: Inside the electrical boxes, red LEDs indicate active inputs. For example, photo eye LEDs (inputs #10, 11, and 12) stay on when no bale is present.
: Always disengage the hydraulic supply before approaching the machine for maintenance. The emergency shut-off is an electrical switch and should not be solely relied upon for physical safety. Bale Band v 2.2
: Set the strapping quantity to "1" on the iBand-It App and run the machine until it indicates it is out of strapping at Position 0. : Inside the electrical boxes, red LEDs indicate
: The hydraulic return line must be connected directly to the tractor's tank to ensure zero back pressure , which is the most common cause of Strap Guide Arm failures. Threading Steel Strapping Correct threading is vital for consistent bundling. The emergency shut-off is an electrical switch and
: The machine must be at Bale Position 0 before starting a new cycle or swapping relay boards.
: Thread the strap through the rod and spring-loaded guide. It must pass between the upper crimp roller and lower bearing.
: Place the new spool; this is recommended as a two-person operation .